Geist Monitored PDU Upgradeable Power Unit Plus Remote Sensing #I20047L

i20047l-p.jpg 

Model Number I20047L -- MN02E4W1-36PT68-3TL6A0A10-S

Geist Monitored PDU Upgradeable Power Unit Plus Remote Sensing #I20047L Features:

Product Summary: 
I20047L -- MN02E4W1-36PT68-3TL6A0A10-S - Monitored, Upgradeable Unit Level Plus Remote Sensing, 30A, 208V, Vertical, (30) Locking IEC C13,(6) Locking IEC C19, breakered, 10 ft power cord with L6-30P, Input power monitoring with breaker level current monitoring. Environmental monitoring via optional remote sensors. Daisy chain Ethernet connectivity. Local high visibility LED display.

Shipping Box DIMS: 86in x 9in x 7in / 2172mm x 223mm x 159mm  

The I20047L -- MN02E4W1-36PT68-3TL6A0A10-S upgradeable unit level power monitoring plus remote sensing PDU delivers a comprehensive view of power usage in a data center, with the added ability to monitor environmental conditions via the Interchangeable Monitoring Device (IMD-02E). The modular design of the PDU allows the hot-swappable IMD-02E to be upgraded as new technology is developed. 

With its current IMD-02E, the I20047L -- MN02E4W1-36PT68-3TL6A0A10-S offers on-board and web power monitoring display options with quick access to the unit's current, volts, real power, apparent power, power factor and kilowatt hours. By monitoring these critical variables, data center managers can evaluate energy usage trends and ensure maximum uptime. The unit's environmental sensor port also gives data center managers the ability to track critical climate variables like temperature, air flow, humidity and dew point, with the use of a Geist remote sensor.

DCIM Enabled - The I20047L -- MN02E4W1-36PT68-3TL6A0A10-S easily integrates with Geist DCIM software, which collects and reports critical power and environmental data for multiple PDUs in a single user interface. Users gain immediate remote access to trends, alarms and histories of devices in the data center through a standard Web browser. Geist DCIM saves both time and cost associated with managing each device individually. Contact your Mainline rep for more details.

Monitoring Input power monitoring with breaker level current monitoring. Environmental monitoring via optional remote sensors. Daisy chain Ethernet connectivity. Local high visibility LED display.
Monitoring Level 1 Phase (A) Monitoring (kWh, W, VA, PF, V, A)

Power Measurements Compliant with ANSI C12.1 and IEC 62053-21 at 1% Accuracy Class Requirements
Monitoring Level 2 Circuit / Breaker Monitoring (A)

Circuit/Breaker Current Measurements Independently Tested and Verified at 2% Accuracy
Quantity Of Inputs 1
Voltage 208V
Current 30A
VA per Input (Load Capacity) 4.9kW
Frequency 50/60 Hz
Over Current Protection (2) 20A Double Pole Magnetic Breakers
Switch Breaker/Switch Combination
Scrolling / Rotatable Digital Display Yes
Power Cable Wire Gauge 10/3
Power Cable Length 10ft
Power Entry Location Bottom Front
Plug Type NEMA L6-30P Twistlock
Combined Total Receptacle/Socket Quantity 36
Receptacle/Socket Type #1 U-Lock IEC C13
Quantity on Face #1 30
Quantity per Breaker #1 15
Color ID #1 2 Circuit = Orange, Green
Style #1 Individual
Voltage per Receptacle/Socket #1 208V
Receptacle/Socket Type #2 U-Lock C19
Quantity on Face #2 6
Quantity per Breaker #2 3
Color ID #2 2 Circuit = Orange, Green
Style #2 Individual
Voltage per Receptacle/Socket #2 208V
Internal RMS Voltage Sensor Yes
Internal RMS Current Sensor Yes
Network Connection Dual 10/100Mbps Ethernet
Network Protocols Supported and Data Access Formats HTTP, HTTPS (TLS 1.2), SMTP, SMTPS (TLS 1.2), ICMP, DHCP, IPv4, IPv6, Syslog, SNMP v1/v2c/v3, JSON, JSON API, RSTP
IP Reset Button Yes
Hard Reboot Button Yes
Remote Sensor RJ Connection Jacks 1 (Supports 4 Sensors)
Continuous Operating Temperature Range Full nameplate operation: 10-45C / 50-113F
Continuous Operating Temperature Range 50% derated operation: 45-60C / 113-140F (See product manual or quick-start guide for full de-rated operating conditions)
Heavy Steel - Powder Coat Finish Black
Configuration 72in / 1832mm Vertical Rackmount
7938 Vertical Mounting Bracket Kit Yes
Toolless Mounting Hardware - Center to Center Spacing 61.25in and 64.75in
Made in the USA Yes
Product Warranty Five Year
Certification/Agency Approvals FCC Part 15 Class A Conformance
Certification/Agency Approvals RoHS Compliant
Certification/Agency Approvals UL & c-UL Listed 60950
Chassis Dimensions (LxWxD) 72in x 2in x 2in

 

Mainline can provide a detailed plan to address your particular requirements.  For assistance on your Data Center Project call Mainline Computer Products for a Free Consultation & Quote toll free at: (800) 686-5312 or Email: Sales@MainlineComputer.com.

 


Write your own product review

Product Reviews

This product hasn't received any reviews yet. Be the first to review this product!




Online Payments